Transducer Block
March 2006
5-61
View Lists
View lists allow the values of a set of parameters to be
accessed at the same time. Views 1 and 2 contain
operating parameters and are defined by the Fieldbus
Foundation. View 3 contains dynamic parameters and
View 4 contains static parameters with configuration
and maintenance information. Views 3 and 4 are
defined by the manufacturer.
Table 5-14. Transducer Block, View 1
Index Number Parameter
1 ST_REV
5.1 MODE_BLK.TARGET
5.2 MODE_BLK.ACTUAL
5.3 MODE_BLK.PERMITTED
5.4 MODE_BLK.NORMAL
6 BLOCK_ERR
10 TRANSDUCER_TYPE
11 XD_ERROR
13.1 FINAL_VALUE.STATUS
13.2 FINAL_VALUE.VALUE
17.1 FINAL_POSITION_VALUE.STATUS
17.2 FINAL_POSITION_VALUE.VALUE
32.1 SETPOINT_D.STATUS
32.2 SETPOINT_D.VALUE
Table 5-15. Transducer Block, View 2
Index Number Parameter
1 ST_REV
10 TRANSDUCER_TYPE
14.1 FINAL_VALUE_RANGE.EU_100
14.2 FINAL_VALUE_RANGE.EU_0
14.3 FINAL_VALUE_RANGE.UNITS_INDEX
14.4 FINAL_VALUE_RANGE.DECIMAL
15 FINAL_VALUE_CUTOFF_HI
16 FINAL_VALUE_CUTOFF_LO
18 SERVO_GAIN
19 SERVO_RESET
20 SERVO_RATE
21 ACT_FAIL_ACTION
40.1 GRANT_DENY.GRANT
40.2 GRANT_DENY.DENY
50 INPUT_CHAR
Note
Because individual views are limited in
size, View Lists 3 and 4 have multiple
parts.
Table 5-16. Transducer Block, View 3.1
Index Number Parameter
1 ST_REV
5.1 MODE_BLOCK.TARGET
5.2 MODE_BLOCK.ACTUAL
5.3 MODE_BLOCK.PERMITTED
5.4 MODE_BLOCK.NORMAL
6 BLOCK_ERR
10 TRANSDUCER_TYPE
11 XD_ERROR
13.1 FINAL_VALUE.STATUS
13.2 FINAL_VALUE.VALUE
17.1 FINAL_POSITION_VALUE.STATUS
17.2 FINAL_POSITION_VALUE.VALUE
32.1 SETPOINT_D.STATUS
32.2 SETPOINT_D.VALUE
35.1 SUPPLY_PRESSURE.STATUS
35.2 SUPPLY_PRESSURE.VALUE
36.1 PRESSURE_A.STATUS
36.2 PRESSURE_A.VALUE
37.1 PRESSURE_B.STATUS
37.2 PRESSURE_B.VALUE
38.1 PRESSURE_DIFF.STATUS
38.2 PRESSURE_DIFF.VALUE
48 TEMPERATURE
49 TRAVEL_TARGET
52 TRAVEL_DEVIATION
53 DRIVE_SIGNAL
54 DRIVE_CURRENT
55 MLFB
59 FAILED_ACTIVE
60 MAINT_ACTIVE
61 ADVISE_ACTIVE
71 RECOMMEND_ACTION
72 TRAVEL_ACCUM
73 CYCLE_COUNT
75.1 INST_ALERTS_ENABLE.ELECT_ENABLE
75.2 INST_ALERTS_ENABLE.SENSOR_ENABLE
75.3 INST_ALERTS_ENABLE.ENVIRO_ENABLE
75.4 INST_ALERTS_ENABLE.TRAVEL_ENABLE
75.5 INST_ALERTS_ENABLE.PROX_ENABLE
75.6 INST_ALERTS_ENABLE.TVL_HISTORY_ENABLE
75.7 INST_ALERTS_ENABLE.PERF_ENABLE
5

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson Fisher Fieldvue DVC6030f and is the answer not in the manual?

Emerson Fisher Fieldvue DVC6030f Specifications

General IconGeneral
BrandEmerson
ModelFisher Fieldvue DVC6030f
CategoryController
LanguageEnglish

Related product manuals