ER5000 Series
21
Features and Specications
ER 5000 Specifications (cont.)
RS485 Communication Interface
Networking: Up to 32 controllers on one network
Maximum cable length: 4000 ft / 1219 m
Baud rate: 9600
Flow Rate
C
v
: 0.01
NOTENOTE
CAUTIONCAUTION
WARNINGWARNING
The ow rate can be increased using a booster regulator.
Accuracy
Room temp: 0.1% of span maximum
Response Time
Rise Time: 257ms — 10 psig to 90 psig / 0.7 bar to 6.2 bar
Fall Time: 552ms — 90 psig to 10 psig / 6.2 bar to 0.7 bar
NOTENOTE
CAUTIONCAUTION
WARNINGWARNING
Step response into dead-end system (1 cubic inch volume).
External Analog Input Impedance
4–20 mA: 250Ω
1–5V: 220KΩ — single input pin to ground
1.7MΩ — differential input
0–10V: 100KΩ
Digital Inputs
Voltage Range/Input Impedance:
4–20 mA: 250Ω
1–5V: 220KΩ — single input pin to ground
1.7MΩ — differential input
0–10V: 100KΩ
Digital Outputs
Current: 50 mA continuous, 100 mA instantaneous
Voltage: 5V to 28V
Type: Open collector, grounded emitter
Analog Output
4–20 mA: Better than 0.5% accuracy;
loads from 50Ω to 100
010V DC: Better than 0.5% accuracy;
loads no less than 5000Ω

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson Tescom ER5000 Series and is the answer not in the manual?

Emerson Tescom ER5000 Series Specifications

General IconGeneral
BrandEmerson
ModelTescom ER5000 Series
CategoryController
LanguageEnglish

Related product manuals