EasyManuals Logo
Home>Emerson>Air Compressor>Vilter VSS

Emerson Vilter VSS User Manual

Emerson Vilter VSS
250 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #112 background imageLoading...
Page #112 background image
5 – 38
Section 5 • Maintenance/Service
VSS/VSM/VSH/VSSH • Installation, Operation and Maintenance Manual • Emerson • 35391SD
Gaterotor Inspection
A) Gaterotor - Main Housing Shelf Clearance
Follow these steps to check the clearance between
the gaterotor and the shelf, which should be between
0.003” – 0.004”, see Figure 5-30.
1. Place a 0.003” feeler gauge between the gaterotor
teeth, as shown in Figure 5-31 (a) and (b).
NOTE
Make sure the feeler gauge stays in the opening between
the two teeth until it is on top of the shelf.
2. Without moving the feeler gauge, slowly rotate the
gaterotor so that the feeler gauge tip stays between
the gaterotor and the shelf. See Figure 5-31 (c).
CAUTION
Do not over rotate. If the rotor catches the feeler
gauge, a piece can break and fall into the rotor groove.
3. Gently pull the feeler gauge out in the direction
shown in Figure 5-31 (d).
Figure 5-30. Gaterotor and Shelf Clearance
Check for 0.003-0.004” (0.076- 0.102 mm) clearance
between gaterotor blade and shelf.
Figure 5-31. Gaterotor and Shelf Clearance Measurement Steps
(a) Feeler Gauge Placement (Side View)
(b) Feeler Gauge
Placement
(Top View)
(c) Tip Of The
Feeler Gauge Stays
Between Gaterotor
And Shelf While
Rotating
(d) Feeler Gauge
Must Be Pulled
Out In This Direc-
tion

Table of Contents

Other manuals for Emerson Vilter VSS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson Vilter VSS and is the answer not in the manual?

Emerson Vilter VSS Specifications

General IconGeneral
BrandEmerson
ModelVilter VSS
CategoryAir Compressor
LanguageEnglish

Related product manuals