2.
On the Scanner Maintenance screen, select Regular Cleaning.
3.
Tap Reset the Number of Scans.
4.
Tap Ye s .
Note:
You can also reset the number of scans by using the following method.
Select Settings and then Device Information. Tap the
icon and tap Number of Scans Aer Regular Cleaning.
Replacing the Roller
e Pickup Roller and the Separation Roller need to be replaced when the number of scans exceeds the life cycle of
the rollers. When a replacement message is displayed on the control panel or your computer screen, follow the
steps below to replace it.
A: Separation Roller, B: Pickup Roller
1.
Press the
P
button to turn
o
the scanner.
2.
Unplug the AC adapter from the scanner.