Working with color alarms and isotherms14
14.1.1 Setting up above, below, and interval alarms
1. Push the navigation pad to display the menu system.
2. Select
(Color) and push the navigation pad. This displays a submenu.
3. Use the navigation pad to select one of the following:
(Above alarm).
(Below alarm).
(Interval alarm).
4. Push the navigation pad. This displays a dialog box where you can define the settings
for the alarm.
For the Above alarm and Below alarm, the following parameters can be set:
Temperature limit.
Palette.
For the Interval alarm, the following parameters can be set:
Low temperature.
High temperature.
Palette.
5. Push the navigation pad. This closes the dialog box.
14.1.2 Building isotherms
Note The Condensation and Insulation alarms are not supported by all camera models.
14.1.2.1 About the Condensation alarm
To detect areas with potential moisture problems, you can use the Condensation alarm.
You can set the relative humidity above which the isotherm will colorize the image.
14.1.2.2 About the Insulation alarm
The Insulation alarm can detect areas where there may be an insulation deficiency in the
building. It will trigger when the insulation level (which is called the thermal index in the
camera) falls below a preset value of the energy leakage through a wall.
Different building codes recommend different values for the insulation level, but typical
values are 60–80% for new buildings. Refer to your national building code for
recommendations.
14.1.2.3 Setting up condensation and insulation alarms
1. Push the navigation pad to display the menu system.
2. Select
(Color) and push the navigation pad. This displays a submenu.
3. Use the navigation pad to select one of the following:
(Condensation alarm).
(Insulation alarm).
#T810413; r. AF/83467/83910; en-US
70

Table of Contents

Other manuals for FLIR T8 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the FLIR T8 Series and is the answer not in the manual?

FLIR T8 Series Specifications

General IconGeneral
BrandFLIR
ModelT8 Series
CategoryThermographic Cameras
LanguageEnglish

Related product manuals