EasyManuals Logo
Home>FLIR>Thermographic Cameras>T8 Series

FLIR T8 Series User Manual

FLIR T8 Series
117 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #99 background imageLoading...
Page #99 background image
Fetching data from external FLIR meters
22
22.4 Typical moisture measurement and
documentation procedure
The following procedure can form the basis for other procedures using FLIR meters and
infrared cameras.
1. Use the infrared camera to identify any potential damp areas behind walls and
ceilings.
2. Use the moisture meter to measure the moisture levels at various suspect locations
that may have been found.
3. When an area of particular interest is located, store the moisture reading in the mois-
ture meter’s memory and identify the measurement area with a handprint or other
thermal identifying marker.
4. Recall the reading from the meter memory. The moisture meter will now continuously
transmit this reading to the infrared camera.
5. Use the camera to take a thermal image of the area with the identifying marker. The
stored data from the moisture meter will also be saved on the image.
22.5 More information
For more information, see the user manuals that are shipped with FLIR meters.
#T810413; r. AF/83467/83910; en-US
92

Table of Contents

Other manuals for FLIR T8 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the FLIR T8 Series and is the answer not in the manual?

FLIR T8 Series Specifications

General IconGeneral
BrandFLIR
ModelT8 Series
CategoryThermographic Cameras
LanguageEnglish

Related product manuals