EasyManuals Logo
Home>Fluke>Data Loggers>1736/FPC

Fluke 1736/FPC User Manual

Fluke 1736/FPC
86 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #41 background imageLoading...
Page #41 background image
Power Logger
Function Selection Buttons
31
2. Push (Correct Digitally) to access the
connection correction screen. This screen allows you
to virtually swap phases and invert the current inputs
instead of a manual correction.
3. If the Logger is able to determine a better phase map
or polarity, push (Auto Correct) to apply the new
settings.
Auto Correct is not available if the algorithm is not able
to detect a better phase map or when no errors are
detected.
Note
It is impossible to detect all incorrect hook-ups
automatically. You must verify the suggested
modifications carefully before you apply the digital
correction. Applications with single-phase energy
generation can deliver the wrong results when you
apply the Auto Correct feature.
The algorithm works in a way that creates in three phase
systems a sequence with a clockwise phase rotation.
Power
– In the Power mode you can get the values and a
live trend chart for each phase (A, B, C or L1, L2, L3) and
total as:
Active Power (P) in W
Apparent Power (S) in VA
Non-active Power (D) in var
Power Factor (PF)
Use (Fundamental/RMS) to toggle between full
bandwidth power values and power of the fundamental.
In the fundamental power screen you see these values:
Fundamental Active Power (P
fund
+) in W
Fundamental Apparent Power (S
fund
) in VA
Fundamental Reactive Power (Q
fund
) in var
Displacement Power Factor (DPF) / cosϕ
Push (Show Menu) to open a list of simplified Power
screens that show all phases and total of one parameter,
all parameters of one phase, or total.

Table of Contents

Other manuals for Fluke 1736/FPC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke 1736/FPC and is the answer not in the manual?

Fluke 1736/FPC Specifications

General IconGeneral
BrandFluke
Model1736/FPC
CategoryData Loggers
LanguageEnglish

Related product manuals