Change Preset Setting (Pressure or RPM)
The preset button allows the operator to go to a pre-programmed pump pressure
or engine RPM during operations. The setting will be shown on the PSI/RPM setting
display. This procedure is to change the setting in the program.
Note: The engine must be running and the pump engaged interlock circuit
must be closed (the OK TO PUMP LED must be on).
1. Press IDLE button.
Result: Display shows IdLE.
2. Press PSI or RPM mode button to select the setting to be changed.
Result: LED indicator goes on for mode selected.
Note: The RPM display must show IdLE before changing the preset.
3. Press and hold PRESET button. (Continue to hold through step 4.)
Result: PUMP DISCHARGE or RPM display flashes previous programmed
preset.
4. Press INC or DEC button to change preset setting.
5. Release PRESET button.
Result: The new preset is programmed. RPM display shows IdLE.