AP-11
APPX. 3 ALERT LIST
This radar provides aggregated header alerts for presentation of an aggregation on the AMS (Alert
Management System). The following table shows the aggregate header alerts along with the cor-
responding ALF alert number.
*: “×” indicates instance number.
The following table lists the possible alerts for this equipment. Each alert is listed with priority and
category. This equipment can output alerts in ALF or ALR format. The alert number depends on
the output format and may differ between formats.
Note: Highlighted alerts have no aggregated alert name.
ALF format alerts
Aggregated Alert Name ALF No.* Aggregated Alert Name ALF No.*
TARGET CAPACITY 3042, × LOST RADAR FUNC 3008, ×
TARGET CAPACITY 3043, × LOST SIGNAL 3015, ×
NEW TARGET 3048, × LOST SIGNAL 3016, ×
LOST TARGET 3052, × WRONG SETTING 3019, ×
Alert ID Alert title Alert Message
Priority &
Category
3042, 1 TT TGT
FULL(AUTO)
"CANCEL NON-DANGEROUS TT TARGETS MANUAL-
LY"
Warning
Cat: A
Meaning: Automatically acquired target capacity has reached 100%.
Remedy: Press the ALARM ACK key. Remove TT symbols manually.
3042, 2 TT TGT
FULL(MAN)
"CANCEL NON-DANGEROUS TT TARGETS MANUAL-
LY"
Warning
Cat: A
Meaning: Manually acquired target capacity has reached 100%.
Remedy: Press the ALARM ACK key. Remove TT symbols manually.
3042, 3 AIS DISPLAY
FULL
"ADJUST [AIS DISP FILTER] SETTINGS" Warning
Cat: A
Meaning: AIS display capacity has reached 100% (350 targets).
Remedy: Press the ALARM ACK key. Adjust [AIS DISP FILTER] settings to decrease the
number of targets displayed.
3042, 4 AIS CPTY
FULL
"ADJUST [AIS DISP FILTER] SETTINGS" Warning
Cat: A
Meaning: AIS capacity has reached 100% (1200 targets).
Remedy: Press the ALARM ACK key. Adjust [AIS DISP FILTER] settings to decrease the
number of targets displayed.
3042, 5 ACTIVE AIS
FULL
"SLEEP NON-DANGEROUS AIS TARGETS MANUALLY" Warning
Cat: A
Meaning: Active AIS target capacity has reached 100% (50 targets).
Remedy: Press the ALARM ACK key. Sleep all unnecessary AIS targets.
3043, 1 TT TGT
95%(AUTO)
"SLEEP NON-DANGEROUS AIS TARGETS MANUALLY" Caution
Cat: B
Meaning: Automatically acquired target capacity has reached 95%.
Remedy: Press the ALARM ACK key. Remove TT symbols manually.