4. INSTALLATION
49
2. Select your transducer and press the EN-
TER key.
Select [600W] for the 600 W transducer,
[1kW] for the 1 kW transducer, not listed
in the following table.
Note: Do not use a 600W transducer in
the 1kW setting. The transducer will be
damaged.
3. Press the MENU/ESC key to finish.
If you have the Tankenmaru system, go to the
next section. To set up external equipment,
go to “NMEA”.
Tankenmaru
The Tankenmaru system outputs the video
signal from your fish finder to a Tankenmaru-
equipped display device, via a radio transmit-
ter. The radio transmitter and display device
are products of the Shimano Corporation. For
how to install the Tankenmaru unit see its in-
stallation manual.
1. Select [Tankenmaru System] from the In-
stallation menu and press the ENTER
key.
2. Select [On] and press the ENTER key to
activate the Tankenmaru system. The
[System] menu changes as below.
3. Press the MENU/ESC key to finish.
NMEA
The NMEA port is disabled when the Tanken-
maru is active.
1. Press the MENU/ESC key.
2. Select [NMEA] from the Installation menu
and press the ENTER key.
Set the menu items according to the equip-
ment connected to the fish finder.
[NMEA0183]: Select NMEA0183 version of
nav equipment connected to "12-24 VDC/
NMEA" port among [Ver 1.5], [Ver 2.0] and
[Ver 3.0].
[NMEA Port]: The NMEA terminals in the "12-
24 VDC/NMEA" port can function as input
ports or input/output port. Change the setting
to "In/In" when connecting GP-320B and a
wind sensor. When connecting the GP-320B
and a wind sensor, first turn on "WAAS Setup"
and then select [In/In] as the [NMEA Port] set-
ting. Only a wind speed/angle sensor that out-
puts the MWV sentence can be connected.
[In/Out]: Input and Output (default setting)
[In/In]: Input only (Available with connection of
both the GP-320B and a wind sensor.)
[NMEA Output]: Select what data sentences
to output.
[Off]: Output the "output data sentences".
[On]: Output the "output data sentences" and
sentences which are input from other equip-
ment.
[WAAS Setup]: Select how to use the WAAS
signal when connecting with a WAAS receiv-
er, for example GP-320B. The message types
(WAAS-00 to WAAS-27) are used as WAAS
correction. Select [WAAS-00] to enable
WAAS.
Note: This function is available only when [In/
Out] is selected at [NMEA Port].
Transducer (option)
600 W 520-5PSD, 520-5MSD, 520-PLD,
525-5PWD, 525T-PWD, 525T-BSD,
525T-LTD/12, 525T-LTD/20,
525STID-MSD, 525STID-PWD,
SS60-SLTD/12, SS60-SLTD/20
1 kW 50/200-1T, 50/200-12M,
526TID-HDD
[Off] selected
(Std. spec.)
Tankenmaru
[On] selected
(Tankenmaru spec.)

Table of Contents

Other manuals for Furuno FCV-587

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Furuno FCV-587 and is the answer not in the manual?

Furuno FCV-587 Specifications

General IconGeneral
BrandFuruno
ModelFCV-587
CategoryFish Finder
LanguageEnglish

Related product manuals