FELCOM 11
G2-3
3. Dip switch setting
1. Remote Alarm setting
The FELCOM 11 can be connected to remote units Distress Message Button IC-300 or
Distress Message Controller DMC-5. Which generates an audible alarm when a distress
alert or urgent message receives. The DIP switch (S2) on the CPU Board function as
below. All bits are set to OFF at factory.
Pin # Type of Alarm OFF ON
3 Distress Enabled Disabled (*1)(*2)
4 Urgent Enabled Disabled (*1)
*1) To change the setting, captain’s agreement is required.
*2) This setting is allowed only when EGC alarm generated from the Terminal Unit can
be heard at the conning place.
CPU Board (16P0108)
CPU
S2
CPU
1234
ON
OFF
S2
Distress
Urgent