FS-5000/8000
A3-13
3. Jumper settings
3.1 For NAV data format selecting, CIF or NMEA
Jumper wire setting on AF board selects data format to be received. Referring to next page.
In addition, system setting for “9933:Data to CIF terminal” port must be set.
[STO] 9 9 3 3 [ENT]
0: MIF(4800bps) 1: TBUS 2: CIF
3: NMEA
4: MIF2(1200bps)
3.2 When using C.Loop between FS-5000/8000 and DB-500
Put a jumper wire on the AF board to use current loop format. Refer to the next page for
locatin of parts on AF board having suffix number –33 and after.
In addition confirm the system setting for “9931:Data to REM 2 terminal” port.
To connect with the DB-500 (C.Loop) or RB-500, setting should be as below.
[STO] 9 9 3 1 [ENT]
0: MIF(4800bps)
1: TBUS 2: CIF
3: NMEA 4: MIF2(1200bps)
Jumper wire: Short (Current Loop)
FS-5000C
Nav device
FURUNO
Radio Equipment
EX)RB-500
or
CIF/NMEA
(TXD/RXD)
TB-4
MIF(4800bps)
NMEA