EasyManuals Logo

Furuno FMD-3100 User Manual

Furuno FMD-3100
395 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #388 background imageLoading...
Page #388 background image
FURUNO
FMD-3100
SP - 2 E4484S01K
170511
2.8 Operation control PING, SNMPv1, v2c, v3
2.9 VLAN Port-base VLAN, IEEE802.1Q Tag VLAN supported,
VLAN IDä –1 to 4094, VLAN registrationä –128 group
2.10 Multiple VLAN Communication between isolated ports is disabled
2.11 Cast control Broadcast, Multicast suppression
3 RADAR OVERLAY (OPTION)
3.1 Picture color Radar picture: 256 colors
3.2 Range 0.125 to 96 NM
3.3 Display mode Heading-up, North-up (heading data required)
3.4 Other functions Off-center, Echo trail, Interference rejection, Anchor watch
4 INTERFACE
4.1 Panel Computer Unit (PCU-3000)
Serial I/O 4 ports (IEC61162-1/2: 2 ports, IEC61162-1: 2 ports)
Data sentences (IEC61162-1/2)
Input ABK, ACN, ALC, ALF, ALR, ARC, CUR, DBT, DPT, DTM, ETL,
GGA, GLL, GNS, HBT, HDT, MTW, MWV, NRX, OSD, PRC, RMC,
ROR, ROT, RPM, RRT, RSA, RSD, THS, TRC, TRD, TTD, TTM,
VBW, VDM, VDO, VDR, VHW, VSD, VTG, XDR, ZDA
Output ABM, ACK, ACN, ALC, ALF, ARC, BBM, DDC, EVE, HBT, OSD,
RRT, VBW, VDR, VSD, XTE
DVI output 2 ports: DVI-D (DVI1), DVI-I or RGB (DVI2)
Note: Full HD monitor required
LAN 1 port: Ethernet, 1000Base-T (for local communication)
USB 4 ports (1 port for control unit), USB2.0 (type-A)
4.2 Sensor adapter (option)
MC-3000S (serial) 8 ports: I/O, IEC61162-1/2: 4 ports, IEC61162-1: 4 ports
MC-3020D (digital-in) 8 ports: relay contact, logics set from program
MC-3030D (digital-out) 8 ports: relay contact, normal open and normal close available
4.3 Ethernet interface for IEC61162-450 (PCU-3000)
Port (LAN2) 1000Base-T, IPv4, 8P8C connector
Data sentences
Input ABK, ACN, ALC, ALF, ALR, ARC, CUR, DBT, DPT, DTM, ETL,
GGA, GLL, GNS, HBT, HDT, MTW, MWV, NRX, OSD, PRC, RMC,
ROR, ROT, RPM, RRT, RSA, RSD, THS, TRC, TRD, TTD, TTM,
VBW, VDM, VDO, VDR, VHW, VSD, VTG, XDR, ZDA
Output ABM, ACK, ACN, ALC, ALF, ARC, BBM, DDC, EVE, HBT, OSD,
RRT, VBW, VDR, VSD, XTE
IEC61162-450 transmission group
Data sentences
Input MISC, TGTD, SATD, NAVD, VDRD, RCOM, TIME, PROP,
USR1 to USR8
Output Arbitrary (default: TGTD)

Table of Contents

Other manuals for Furuno FMD-3100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Furuno FMD-3100 and is the answer not in the manual?

Furuno FMD-3100 Specifications

General IconGeneral
BrandFuruno
ModelFMD-3100
CategoryMarine Equipment
LanguageEnglish

Related product manuals