6 Commissioning
6.1 Lift Sequences
6.2 Preliminary Operations
The drive can be configured in two modalities, Easy (only the main parameters are displayed) and Expert (all parameters are
displayed). The mode can be selected by parameter:
6.2.1 Set the motor type
Load Async / Sync Control
If a different type is selected, the drive must be switched off and then switched on.
6.2.2 Set the units for the car speed
Travel Units sel (Hz, m/s, rpm)
To select m/s set to 1, in rpm (speed of the motor shaft) set to 2, in feet per minute set to 3.
Acc ini jerk
Acceleration
Dec ini jerk
Deceleration
Dec end jerk
End decel
Brake open delay
Run Cont Close delay
Spd 0 ref delay
Brake close dly
Start / Rev cmd
Mlt spd s 0
Mlt spd s 1
Mlt spd s 2
Speed ref 1
Magn. current
Slow Down dist
Acc end jerk
HW Enable
Spd 0 ref thr
Run Cont open delay