Flying Shear for Roll Forming machines Instruction manual Pag. 12 / 29
The following drive configurations are required:
Basic parameters configuration
Digital I/O
Encoders
Field bus
4.2.1 Basic parameters configuration
After loading the default application parameters (Load default, PAR 11100), the basic drive parameters are
configured.
Table 2 shows the configurations loaded.
PARAMETER
SETTING
PAR
MENU
PARAMETER
552
DRIVE CONFIG
Regulation mode
556
DRIVE CONFIG
Control mode select
752
RAMPS
Ramp out zero src
650
REFERENCES
Dig speed ref 2
1000
COMMANDS
Commands remote sel
1004
COMMANDS
Enable/disable mode
1010
COMMANDS
Commands safe start
1018
COMMANDS
Digital Enable src
1020
COMMANDS
Digital Start src
1022
COMMANDS
Fast Stop src
1314
DIGITAL OUTPUT
Digital Output 3 src
4452
WORD DECOMP
Word decomp src
4500
ALARM CONFIG
Fault reset src
Table 2: Parameters loaded using Load Default