54
English
Appendix
Site Requirements
• Uninterrupted Power System (UPS) - minimum rating of 450VA,
with AC Power Stabilizer (Recommended for continuous
plotting)
• Temperature Range: 15-35 C (59-95 F)
• Humidity: 20% - 80% (non-condensing)
Technical Specifications
Print Engine
• Infinity 45 - Single HP type 51645A
• Infinity 85 - HP long-life ink delivery system
(alternate configuration - two HP 51645A cartridges)
Host Connectivity
• RS-232 - baud rates to 57600 bps (Infinity 45/85)
• Direct 10-base T Ethernet interface (Infinity 85)
Paper
• Paper widths in continuous rolls from 914 mm-1828 mm (36-72
in.)
• Plot width to 1816 mm (71.5 in.)
• Paper rolls up to 241 mm (9.5 in.) with an inner core of 76 mm
(3 in.)
Floor Space Requirements
• 685 mm x 2794 mm (27 in. x 110 in.)
Weight
• 122 kg (270 lbs.)
Power Requirements
The Infinity is connectable to any standard electrical source
• 115/230 VAC +/- 10%
• Single phase, 47-63 Hz
• 1 KVA