Trouble Communicating Over the Network
Verify the proper network serial (Figure 38) and connection
settings (Figure 39) on the plotter:
1. Open the Infinity 85 Network Setup program by selecting
Start/All Programs/Lantronix/DeviceInstaller.
2. Expand the selections until the desired plotter
corresponding to the IP or MAC address number
recorded earlier is displayed.
3. Once an IP has been assigned, highlight the desired
plotter entry (in the left hand panel) and click on the Web
Configuration tab in the right panel.
4. Ensure that the assigned IP address is listed in the
Address field and click Go. If prompted for a username
and password, just click Ok.
5. Once the Device Server Configuration Manager has
loaded, click on Serial Settings. Set the Baud Rate to
57600 and click on OK.
6. Click on Connection and set the Local Port to 9221.
Click OK and then click on Apply Settings.
Figure 38. Serial Settings

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gerber Technology GERBERplotter Infinity Series and is the answer not in the manual?

Gerber Technology GERBERplotter Infinity Series Specifications

General IconGeneral
BrandGerber Technology
ModelGERBERplotter Infinity Series
CategoryPlotter
LanguageEnglish

Related product manuals