Prime
38 312359R
Prime Solvent Flush Pump
1. Connect ground wire to a metal pail of solvent.
2. Place siphon tube in the pail of solvent.
3. Open solvent flush valve (AK) on mix manifold.
4. Ensure trigger lock is engaged. Remove spray tip.
5. Disengage trigger lock and trigger gun into a
grounded pail. Use a pail lid with a hole to dispense
through. Seal around hole and gun with a rag to
prevent splash back. Be careful to keep fingers
away from front of gun.
6. Open solvent pump air valve (CB). Pull out and
slowly turn solvent pump air regulator (CG)
clockwise to prime solvent pump and push air out of
mix hose and gun. Trigger gun until all air is purged.
7. Close solvent pump air valve (CB) and trigger gun
to relieve pressure. Engage gun trigger lock.