I. Manufactured Home Installation
YoumustuseaHarman®OutsideAirKitforinstallationina
manufactured home.
1. An outside air inlet must be provided for the combustion
airandmustremainclearofleaves,debris,iceand/or
snow. It must be unrestricted while the appliance is in
use to prevent room air starvation which causes smoke
spillage.Smokespillagecanalsoseto󰀨smokealarms.
2. The combustion air duct system must be made of metal.
Itmustpermitzeroclearancetocombustibleconstruction
and prevent material from dropping into the inlet or into
the area beneath the dwelling and contain a rodent
screen.
3. The appliance must be secured to the manufactured
homestructurebyboltingittotheoor(usinglagbolts).
Use the sameholes thatsecured the appliance to the
shipping pallet.
4. The appliance must be grounded with #8 solid copper
grounding wire or equivalent, terminated at each end
with an NEC approved grounding device.
5. Refer to “Clearances to Combustibles and Floor
Protection” section of this manual for listings to
combustibles.
6. Use silicone to create an e󰀨ective vapor barrier at
the location where the chimney or other component
penetratestotheexteriorofthestructure.
7. Follow the chimney manufacturer’s instructions when
installing the vent system for use in a manufactured
home.
8. InstallationshallbeinaccordancewiththeManufacturers
Home&SafetyStandard(HUD)CFR3280,Part24.
THE STRUCTURAL INTEGRITY OF THE
MANUFACTUREDHOMEFLOOR,WALLANDCEILING/
ROOFMUSTBEMAINTAINED.
DoNOTcutthrough:
Floor joist, wall, studs ceiling trusses.
• Anysupportingmaterialthatwoulda󰀨ectthestructural
integrity.
SparkArrestorCap
RoofFlashing
ApprovedClass”L”or
“PL”PelletVent
JoistShield/Firestop
StormCollar
Asphyxiation Risk:
NEVERINSTALLINTOASLEEPINGROOM
Consumesoxygenintheroom
WARNING
Installation must comply with Manufactured Home
and Safety Standard (HUD), CFR 3280, Part 24
WARNING
CAUTION
Never draw outside combustion air from:
Wall,oororceilingcavity.
Enclosed space such as an attic or garage.
CAUTION

Other manuals for Harman P42i-TC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Harman P42i-TC and is the answer not in the manual?

Harman P42i-TC Specifications

General IconGeneral
BrandHarman
ModelP42i-TC
CategoryIndoor Fireplace
LanguageEnglish

Related product manuals