Harman® • P42i Pellet Insert Installation Manual • 2023 -___ • 08/239 8742-901D
B. Clearances to Combustibles & Floor
Protection
When selecting a location for the appliance it is important to
considertherequiredclearancestowalls(seeFigure3.2).
WARNING! Risk of Fire or Burns! Provide adequate
clearance around air openings and for service access. Due
to high temperatures, the appliance should be located out
oftracandawayfromfurnitureanddraperies.
NOTICE: IllustrationsreecttypicalinstallationsandareFOR
DESIGNPURPOSESONLY.Illustrations/diagramsarenot
drawn to scale. Actual installation may vary due to individual
design preference.
Floor protection must be used from hearth
opening to 6" (152mm) in front ofdoor
glassand6"(152mm)toeachsideofthe
door opening OR 8” (203mm) to sides
to protect combustibles from hot ashes.
A minimum size will be 17" deep by 30"
wideandbemadeofanon-combustible
materialormeetULapproval.
Figure 3.2
A = to sidewall
B = to 12" mantel
C=to3/4"trim
D=to3/4"trim
E=oorprotection
12” (305mm) Mantel
B
A
E
E
C
D
Clearances: A B *C D E (From Glass)
From Insert Body: 12”(305mm) 12”(305mm) 0” 8”(203mm) 6”(152mm)
*3/4 Trim, Zero Clearance to Surround
G
H
F
Location Inches Millimeters
F MinimumWidth 24-7/8 632
G MinimumDepth 15-9/16 395
H MinimumHeight(24”Hopper)
24 610
H MinimumHeight(20”Hopper) 20 508
C. Minimum Opening - Masonry and Manufactured Fireplaces
CAUTION
HearthandHomeTechnologiesdoesnotrecommendadhesive
based vinyl ooring due to thermal expansion. Floating-style
ooring(LVP-luxuryvinylplankorLVT–luxuryvinyltile)canbe
used, but it will reach temperatures up to 110 °F in a room with
ambienttemperatureof70°F.Consultooringspecicationsto
ensure compatibility.
HHTrecommendswoodstovesandinsertshave29inchesof
alternativeooringinfrontofthestovebeforeusingLVP/LVT
regardless if they sit ush on the oor or are elevated on a
raised hearth.
Forallotherooring,continuetofollowclearancetocombustible
requirements in the installation manual.
NOTICE: Clearances that do not meet the minimum guidelines
couldresultindamageorbucklingtothevinylooringandis
done at the installer’s risk.

Other manuals for Harman P42i-TC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Harman P42i-TC and is the answer not in the manual?

Harman P42i-TC Specifications

General IconGeneral
BrandHarman
ModelP42i-TC
CategoryIndoor Fireplace
LanguageEnglish

Related product manuals