7. Set the Wireless Supervision Time, and the system determines
connecon fault if the
disconnected duraon of the device is longer than the congured value.
8. Click OK.
Note
Aer the sounder is congured, you can click Device Status → Sounder to view the sounder
status.
Output
If you want to the link the device with a relay output to output the alarm, set the output
parameters.
Steps
1. In the client
soware, select the device on the Device Management page and click , or enter
the device IP address in the address bar of the web browser and log in.
2. Click
Conguraon → Device Management → Relay to enter the Output page.
3. Click
and the Output Sengs window will pop up.
Figure 4-22 Output Sengs
4. Edit the relay name and select a link event.
5. Enable LATCH PULSE or set the output delay
me.
Note
If the relay has linked to the wireless output module, the wireless output module informaon
will be displayed in the Enroll Wireless Output Module area.
6. Check Event Type .
7. Check areas linked to the relay. (Zone and Manual event do not have this parameter.)
8. Select to enable Contact Status or not. (Only for Arm and Disarm.
Hybrid Security Control Panel User Manual
36