Reason of Arming Failure
• Intrusion detector triggered (excepts the detector on the exit route).
• Panic alarm device triggered.
• Tampering alarm occurred.
• Communicaon excepon
• Main power supply
excepon
• Backup
baery excepon
• Alarm receiving fault
• Sounder fault
• Low baery of the keyfob
• Others
Arming with Fault
While the arming is stopped with fault, user in level 2 has the permission to arm the system with
fault (forced arming).
Fored arming only taks eect on the current arming operaon.
The forced arming operaon will be record in the event log.
5.2 Disarming
You can disarm the system with keypad, keyfob, card, client soware, or mobile client.
Disarming Indicaon
The arming/disarming indicator ashes 30s while the user successfully disarm the system through
the entry/exit route.
The system will report the disarming result
aer the operaon completed.
Entry Delay Duraon
Ensure that mer is no longer than 45 seconds in order to comply with EN50131-1.
Early Alarm
If either the intrusion or tampering alarm occurs on the enter/exit route when the control panel is
in the status of entry delay, the control panel then enters the early alarm mode.
The early alarm
duraon can be set (> 30s).
The control panel will reports the alarm only if the alarm event lasts over the duraon of early
alarm with the addion of entry delay.
5.3 Use the Keyfob
The keyfod is used for away arming, stay arming, disarming, panic alarm, and clearing alarm.