Page #40 background imageLoading...
Page #40 background image
Note
You can set 2 dierent me duraons in Area Management → Schedule & Timer .
Follow Zone
The zone acts as delayed zone when it detects triggering event during system Entry Delay,
while it acts as instant zone otherwise.
Perimeter Zone
The system will immediately alarm when it detects a triggering event
aer the system is
armed. There is a
congurable interval mer between the alarm acvaon and sounder
output "Sounder Delay Time (Perimeter Alarm) 0 to 600 Seconds". This
opon allows you to
check the alarm and cancel the sounder output during the interval me in case of false
alarm.
When the zone is armed, you can set the peripheral alarm delayed
me in Area
Management → Schedule & Timer . You can also mute the sounder in the delayed me.
Silent Panic Zone
This zone type is acve 24hrs, it is used for Panic or HUD (Hold Up Devices) not smoke
sensors or break glass detectors.
Panic Zone
The zone
acvates all the me. It is usually used in the sites equipped with panic buon,
smoke detector and glass-break detector.
Fire Zone
The zone acvates all the me with sound or sounder output when alarm occurs. It is usually
used in
re hazardous areas equipped with smoke detectors and temperature sensors.
Gas Zone
The zone acvates all the me with sound or sounder output when alarm occurs. It is usually
used in areas equipped with gas detectors (e.g., the kitchen).
Medical Zone
The zone acvates all the me with beep conrmaon when alarm occurs. It is usually used
in places equipped with medical emergency
buons.
Timeout Zone
The zone acvates all the me. The zone type is used to monitor and report the "ACTIVE"
status of a zone, but it will only report and alarm this status aer the programmed me has
expired. (1 to 599) Seconds. It can be used in places equipped with
magnec contacts that
require access but for only a short period (e.g., re hydrant box's door or another external
security box door)
Disabled Zone
Alarms will not be
acvated when the zone is triggered or tampered. It is usually used to
disable faulty detectors.
Hybrid Security Control Panel User Manual
32

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HIKVISION DS-PHA64-M and is the answer not in the manual?

HIKVISION DS-PHA64-M Specifications

General IconGeneral
BrandHIKVISION
ModelDS-PHA64-M
CategoryControl Panel
LanguageEnglish

Related product manuals