80
Chapter 12 Exception
Purpose:
The exception type can be HDD error, network disconnected, IP address conflicted, and vehicle
detector exception.
Go to Configuration > Device Configuration> Exception.
Select the exception type and the corresponding trigger methods.
Exception Settings
Notify Surveillance Center: Send an exception or alarm signal to remote management
software when an event occurs.
Trigger Alarm Output: Trigger one or more external alarm outputs when an event occurs.
Alarm Dwell Time(s): The waiting time for the alarm triggered. And you can set the alarm
dwell time from 0 to 180s.
Click Save to save the settings.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HIKVISION iDS-TCV500-BI and is the answer not in the manual?

HIKVISION iDS-TCV500-BI Specifications

General IconGeneral
Card reader integratedYes
Maximum memory card size128 GB
Maximum resolution2464 x 2056 pixels
Image quality adjustmentSaturation, Brightness, Contrast, Sharpness, DNR
Video compression formatsH.264, H.265
Placement supportedOutdoor
Signal-to-Noise Ratio (SNR)60 dB
Number of users32 user(s)
Supported network protocolsTCP/IP, HTTP, HTTPS, FTP, DNS, DDNS, RTP, RTSP, RTCP, NTP, UPnP, IPv6, UDP
FocusMotorized/Manual
Minimum illumination0.001 lx
Housing materialAluminum
International Protection (IP) codeIP66