EURO 46 V10 Programming Manual
3. The LCD will now display ‘Delete Users And Fobs?’. Press
and ‘Are you Sure?’ will be asked. Press to delete
all users or to go back.
PLEASE NOTE: This is not reversible.
4. ‘Change Duress Codes’ will be displayed. Press to
add any Duress, Guard or Dial out codes or press .
5. ‘Change Master Manager Code’ will be displayed. Press
to change the Master Manager code or press .
6. ‘Change Engineer Code’ will be displayed. Press
to change the Engineer code or press to return to
the Engineer menu.
Volume Control?
The Volume Control function applies to both the main sounder, the on-board keypad or any additional
keypads.
Area A,B,C,D,0,1 Entry Tone Volume
0=Completely Silent, 1=Silent, but beeps when the system is set. 2-5 keypad 6&7 = Main Sounder
Area A,B,C,D,0,1 Exit Tone Volume
0=Completely Silent, 1=Silent, but beeps when the system is set. 2-5 keypad 6&7 = Main Sounder
Area A,B,C,D,0,1 APP Exit Tone Volume
0=Completely Silent, 1=Silent, but beeps when the system is set. 2-5 keypad 6&7 = Main Sounder
Alarm Volume
0=Completely Silent, 1=Silent, but beeps when the system is set. 2-5 keypad 6&7 = Main Sounder
Fire Alarm Volume
0=Completely Silent, 1=Silent, but beeps when the system is set. 2-5 keypad 6&7 = Main Sounder
Tamper Alarm Volume
0=Completely Silent, 1=Silent, but beeps when the system is set. 2-5 keypad 6&7 = Main Sounder
Day Alarm Volume
0=Completely Silent, 1=Silent, but beeps when the system is set. 2-5 keypad 6&7 = Main Sounder
Chime Volume
0=Completely Silent, 1=Silent, but beeps when the system is set. 2-5 keypad 6&7 = Main Sounder
Code Stops Sound
If this function is enabled, then once an alarm has been generated (even if the code is not
programmed for that area) the alarm will be silenced, and a ‘Misoperation (Abort) signal’ will be sent.
The area will remain set until a code or tag is presented that is assigned to that area.
Change Duress
Codes?
Change Master
Manager Code?
Change Engineer
Code?
Change Duress
Codes?

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HIKVISION Pyronix EURO 46 V10 and is the answer not in the manual?

HIKVISION Pyronix EURO 46 V10 Specifications

General IconGeneral
BrandHIKVISION
ModelPyronix EURO 46 V10
CategorySecurity System
LanguageEnglish

Related product manuals