36
OPERATION
Voltage Selector Switch
The power available to each receptacle depends on the position of the
voltage selector switch.
120V ONLY Position
When the voltage selector switch is in the 120V ONLY position, you do
not need to spread the load over the receptacles. You must, however,
make sure the load on any receptacle does not exceed its available
power shown in the table above and the total load does not exceed
the total current available.
Total Current Available:
30.0 A (EM4000SX)
37.5 A (EM5000SX)
45.8 A (EM6500SX)
Switch
Position
Receptacle
Available Power
EM4000SX EM5000SX EM6500SX
120V ONLY
30A at 120V 30A at 120V 30A at 120V
20A at 120V 20A at 120V 20A at 120V
20A at 120V 20A at 120V 20A at 120V
20A at 120V 30A at 120V 30A at 120V
None None None
120V/240V
15.0A at 120V
18.8A at 120V
22.9A at 120V
15.0A at 120V
18.8A at 120V
20A at 120V
15.0A at 120V
18.8A at 120V
20A at 120V
-
15.0A at 240V
18.8A at 240V
22.9A at 240V