1-22
Introduction
PoE Capabilities of the Products
Introduction
Configuring PoE Redundancy
When considering redundant power, also consider the power source for the
power supplies. Each power supply should be connected to a separate power
source circuit in order to supply complete redundancy. Should one circuit fail,
it would then be possible for the other circuit to continue supplying power to
the second power supply in the switch, keeping the switch running.
When PoE redundancy is enabled, PoE redundancy occurs automatically. The
switch keeps track of power use and won’t supply PoE power to additional
PoE devices trying to connect if that results in the switch not having enough
power in reserve for redundancy if one of the power supplies should fail. There
are three configurable redundancy methods:
No PoE redundancy enforcement (default). All available power can be
allocated.
Full redundancy: half of the totally available PoE power can be allocated
and half is held in reserve for redundancy. If power supplies with different
ratings are used, the highest-rated power supply is held in reserve to
ensure full redundancy.
N+1. One of the power supplies is held in reserve for redundancy. If a
single power supply fails, no powered devices are shut down. If power
supplies with different ratings are used, the highest-rated power supply is
held in reserve to ensure full redundancy.
Note When changing from one method to another, always check the current level
of PoE usage before implementing the change. The change could cause
existing connection to lose PoE power.
When considering redundant power, also consider the power source for the
power supplies. Each power supply should be connected to a separate power
source circuit in order to supply complete redundancy. Should one circuit fail,
it would then be possible for the other circuit to continue supplying power to
the second power supply in the switch, keeping the switch running.

Table of Contents

Other manuals for HP PROCURVE 2520

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP PROCURVE 2520 and is the answer not in the manual?

HP PROCURVE 2520 Specifications

General IconGeneral
BrandHP
ModelPROCURVE 2520
CategorySoftware
LanguageEnglish

Related product manuals