2-6
Operating Rules
Configuring PoE/PoE+ Power Using the CLI
Operating Rules
Threshold
You can configure one of the following thresholds:
A global power threshold that applies to all modules on the switch.
This setting acts as a trigger for sending a notice when the PoE power
consumption on any PoE module installed in the switch crosses the
configured global threshold level. (Crossing the threshold level in
either direction—PoE power usage either increasing or decreasing—
triggers the notice.) The default setting is 80%.
A per-slot power threshold that applies to an individual PoE module
installed in the designated slot. This setting acts as a trigger for
sending a notice when the module in the specified slot exceeds or
goes below a specific level of PoE power consumption.
For example if the threshold is set at 50%, the switch informs you that the
switch has exceeded the threshold when 51% of available PoE power is being
used.
For more information, see the Management and Configuration Guide on the
ProCurve Web site at:
www.hp.com/go/procurve/manuals

Table of Contents

Other manuals for HP PROCURVE 2520

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP PROCURVE 2520 and is the answer not in the manual?

HP PROCURVE 2520 Specifications

General IconGeneral
BrandHP
ModelPROCURVE 2520
CategorySoftware
LanguageEnglish

Related product manuals