Specifications 86
Specifications
Environmental specifications
Specification Value
Temperature
Operating
1
10°C to 35°C (50°F to 90°F)
Non-operating 30°C to 60°C (-22°F to 140°F)
Maximum rate of temperature
change
Operating
2,3
10°C/hr (18°F/hr)
Non-operating 20°C/hr (36°F/hr)
Relative humidity
(noncondensing)***
Operating 10% to 90%
Non-operating 5% to 95%
Maximum wet bulb temperature
(non-condensing)
Operating 28°C (82.4°F)
Non-operating 38.7°C (101.7°F)
Altitude
Operating
2
3,050 m (10,000 ft)
Non-operating 9144 m (30,000 ft)
Maximum rate of altitude
change
Operating 457 m/min (1,500 ft/min)
Non-operating 457 m/min (1,500 ft/min)
1
All temperature ratings shown are for sea level. An altitude derating of 1°C per 300 m (1.8°F per 1,000 ft) to 3048
m (10,000 ft) is applicable. No direct sunlight allowed.
2
The type and number of options installed can limit the upper limit.
3
System performance may be reduced if operating with a fan fault above 30ºC (86ºF).
Mechanical specifications
Specification Value
Dimensions
Height 4.32 cm (1.69 in)
Depth 70.00 cm (27.56 in)

Table of Contents