Removal and Replacement Procedures
2-4 HP ProLiant ML150 Generation 2 Server Maintenance and Service Guide
HP CONFIDENTIAL Codename: Stone Soup 2 Part Number: 368148-003 Last Saved On: 6/10/05 4:28 PM
Preparation Procedures
WARNING: Only authorized technicians trained by HP should attempt to repair this
equipment. Because of the complexity of the individual boards and subassemblies, no
one should attempt to make repairs at the component level or to make modifications to
any printed wiring board. Improper repairs can create a safety hazard.
CAUTION: Electrostatic discharge (ESD) can damage electronic components. Be sure that
you are properly grounded (earthed) before beginning any installation procedure. Refer to
“Electrostatic Discharge Information” earlier in this chapter for more information.
Before removing any serviceable parts, determine whether the part is hot-pluggable or
non-hot-pluggable.
Non-Hot-Pluggable Device
If the device is non-hot-pluggable, the server must be powered down. Non-hot-pluggable
devices in the server include the processor, all boards, memory modules, fans, PCI option
cards and drive cages.
Powering Down the Server
WARNING: To reduce the risk of injury from electric shock, disconnect all power cords
to completely remove power from the system.
WARNING: To reduce the risk of personal injury from hot surfaces, allow the internal
system components to cool before touching them.
CAUTION: Protect the server from power fluctuations and temporary interruptions with a
regulating uninterruptible power supply (UPS). This device protects the hardware from
damage caused by power surges and voltage spikes, and keeps the system in operation
during a power failure.
CAUTION: The server must always be operated with system unit covers on. Proper cooling is
not achieved when the system unit covers are removed.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProLiant ML150 Generation 2 and is the answer not in the manual?

HP ProLiant ML150 Generation 2 Specifications

General IconGeneral
BrandHP
ModelProLiant ML150 Generation 2
CategoryServer
LanguageEnglish

Related product manuals