100 ArcGlide THC Instruction Manual 806450
2 – Installation
Hypernet and HMI interface cable
In a Hypernet or mixed configuration where there is more than one Hypernet connection, use these cables to connect the
components of the system to the Ethernet switch.
If you use Ethernet cable from another supplier, make sure that the cable is a standard, shielded RJ-45 Cat5e or Cat6
cable.
Part number Length Part number Length
223212 3.0 m (10 feet) 223099 23.0 m (75 feet)
223222 6.0 m (20 feet) 223100 30.5 m (100 feet)
223119 7.5 m (25 feet) 223101 45.5 m (150 feet)
223223 10.5 m (35 feet) 223102 61.0 m (200 feet)
223008 15.0 m (50 feet)
Pin No.* Signal name
1 Tx + (transmit data +)
2 Tx - (transmit data -)
3 Rx + (receive data +)
4 Not connected
5 Not connected
6 Rx - (receive data -)
7 Not connected
8 Not connected
* Pin numbers are the same on both ends of the cable.
Diameter = 6.35 mm (0.25 inch)
Bend radius = 152.40 mm (6.00 inch)
Connect one end to the control module or Ethernet switch.
Connect the other end to the ArcGlide HMI.