ArcGlide THC Instruction Manual 806450 211
4 – Maintenance
ArcGlide PCBs
HMI processor board (228581)
In a Hypernet configuration, the Unit address switch (SW6) on the HMI processor board
must have the same address as the Unit address switch on the THC processor and the
Hypernet plasma interface boards. The default setting is 1.
Test points
Test point No. Signal
TP10 +2.5 VDC
TP33 +3.3 VDC
TP37 +5 VDC
TP38 Ground
J4 LCD character module
Pin No. Signal Pin No. Signal
1 DB6 2 DB7
3 DB4 4 DB5
5 DB2 6 DB3
7 DB0 8 DB1
9 WR\ 10 E1 (lines 1 and 2)
11 Vee 12 RS
13 VOC 14 Vss
15 Not connected 16 E2 (lines 3 and 4)
Default settings = 1
TP10
J4 LCD character module
J3 Display ribbon cable
SW6 Unit address switch,
default setting = 1
J7 RJ45
J11 Rotary encoder input
J8 Operator console
LEDs
J10 IHS test
pushbutton
J9 Display J12 Power input
TP 37
TP 38
TP 33
1
1
1
1
1
1
1
1
1