EasyManuals Logo
Home>Hypertherm>Control Systems>ArcGlide THC

Hypertherm ArcGlide THC User Manual

Hypertherm ArcGlide THC
288 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #284 background imageLoading...
Page #284 background image
284 ArcGlide THC Instruction Manual 806450
B ArcGlide THC Serial Communication Installation
Plasma board adapter cable (223260)
Connector A
Pin No.
Wire
color
Signal
Connector B
Pin No.
6
7
White
Black
Motion +
Input common -
28
9
18
19
White
Brown
Pierce output A
Pierce output B
13
32
20
21
White
Red
Hold output A
Hold output B
14
33
22
23
White
Orange
Start output A
Start output B
15
34
28
31
White
Yellow
Field common
Plasma 24 V field
18
37
34
35
White
Green
1/50 Arc Voltage +
1/50 Arc Voltage -
35
16
Connects the plasma cable to J5 on the plasma board.
Length = 520.70 mm (20.50 inch)
Diameter = 12.70 mm (0.50 inch)
Bend radius = 152.40 mm (6.00 inch)
Connector A Connector B
1
18
1
50
33
37
19
20
17
34