98 ArcGlide THC Instruction Manual 806450
2 – Installation
Lifter interface cable
Part number Length Part number Length
223219 3.0 m (10 feet) 223115 23.0 m (75 feet)
223220 6.0 m (20 feet) 223116 30.5 m (100 feet)
223120 7.5 m (25 feet) 223117 45.5 m (150 feet)
223221 10.5 m (35 feet) 223118 61.0 m (200 feet)
223007 15.0 m (50 feet)
Pin No.* Color and size Signal name
1 Red 1.31 mm
2
(16 AWG) Motor +
2 Black 1.31 mm
2
(16 AWG) Motor -
3 Black 0.82 mm
2
(18 AWG) Brake -
4 Brown 0.33 mm
2
(22 AWG) Common -
5 Brown 0.82 mm
2
(18 AWG) Power +24 VDC
6 Gray 0.33 mm
2
(22 AWG) Ohmic contact sense common
7 White 0.33 mm
2
(22 AWG) Ohmic contact sense
8 Violet 0.33 mm
2
(22 AWG) Ohmic contact sense bias +12 VDC
9 Black 0.33 mm
2
(22 AWG) Encoder common
10 Red 0.33 mm
2
(22 AWG) Lifter station active
11 White/Blue 0.33 mm
2
(22 AWG) Encoder input B -
12 Blue 0.33 mm
2
(22 AWG) Encoder input B +
13 White/Yellow 0.33 mm
2
(22 AWG) Encoder input A -
* Pin numbers are the same on both ends of the cable.
Red band
Diameter = 20.07 mm (0.79 inch)
Bend radius = 150.00 mm (6.00 inch)
Connect one end to the port on the control
module with the red circle. Connect the other
end to the top of the lifter.