ArcGlide THC Instruction Manual 806450 229
4 – Maintenance
LEDs
LED No. Color Signal
1 Red Plasma system error
2 Slow blinking red HPR Hypernet is ready
3 Rapid blinking red Serial transmission
J3 Discrete interface
Pin No. Signal Pin No. Signal
1 Start + 2 Start -
3 Hold + 4 Hold -
5 Pierce + 6 Pierce -
7 Corner + 8 Corner -
9 Not ready C 10 Not ready E
11 Ramp down error C 12 Ramp down error E
13 HPR error C 14 HPR error E
15 Transfer (Motion) C 16 Transfer (Motion) C
J4 Arc voltage*
Pin No. Signal
1 Work +
2 Electrode -
* The arc voltage terminals on connector J4 must be connected to the I/O board in the plasma system.
J5 CNC interface
Pin No. Signal Pin No. Signal
1 HPR Rx - 2 HPR Tx -
3 RS-422 Common 4 Motion
5 Error 6 Rampdown error
7 HPR not ready 8 Not connected
9 Not connected 10 Not connected
11 Not connected 12 Spare
13 Pierce A 14 Hold A
15 Start A 16 Not connected
17 Not connected 18 Ground
19 Not connected 20 HPR Rx +
21 HPR Tx + 22 Not connected
23 Motion 24 Error
25 Rampdown error 26 HPR not ready