APPENDIX A: ARGON-HYDROGEN CUTTING AND GOUGING
a-2 HySpeed HT2000LHF Instruction Manual
6
Argon-Hydrogen supply to Argon-Hydrogen Manifold
• Attach one end of the supply hose to the argon-hydrogen supply tank regulator, and attach the other end to
the argon-hydrogen supply hose connection on the manifold. (Figure a-2)
Figure a-2 Argon-Hydrogen Manifold Connection Points
Cable Connection Point
Plasma Gas
Torch Lead
Connection
Argon-Hydrogen
Supply Hose
Connection
Argon-Hydrogen Cable – Argon-Hydrogen Manifold to Power Supply
1. Connect the receptacle end of the argon-hydrogen cable to the cable connection point on the argon-
hydrogen manifold. (Figure a-2)
2. Connect the other end of the cable to TB4 (smaller terminal strip on the inside rear panel of the power
supply). Match up wires 102, 103, 13 and 14 to wires already connected to the strip. Connect the two
shield wires to points labeled as PE (protective earth).
Part No. Length
023660 15 ft (4.6 m)
023661 25 ft (7.6 m)
023662 50 ft (15 m)
023663 75 ft (23 m)
023664 100 ft (30 m)
023665 150 ft (46 m)
13
13
14X1
13
14
etc.
14x1 TB4 Color Signal
1 13 Red PS1 / Plasma
2 14 Black PS1 / Plasma
12 Shield Shield
3 102 Green SV5 / Plasma Off
4 103 Black SV5 / Plasma Off
9 Shield Shield