SPECIFICATIONS
HySpeed HT2000LHF Instruction Manual 2-3
6
Power Supply
Maximum OCV (U
0
)......................................................280 VDC
Output Current (I
2
) ........................................................40 – 200 amps
Output Voltage (U
2
) ......................................................150 VDC
Duty Cycle Rating (X) ..................................................100% up to 30 kW. Beyond 30 kW, Duty Cycle (X) =
(30 kW/Actual Power)
2
Eg: If Actual Power = 32 kW, then Duty
Cycle (X) = (30 kW/32 kW)
2
= 88%
Ambient Temperatures/Duty Cycle ...............................Power supplies will operate between +14° and 104° F (-10° and
+40° C). Power supplies operated in an ambient temperature
above 86° F (30° C) may show some decrease in duty cycle.
Power Factor (cos
ϕ
) .....................................................0.86
Input Power (Input Voltage (U
1
) x Input Current ( I
1
)):
073227 with THC; 073228 without THC .......................200 VAC, 3PH, 50 Hz, 108 amps
073229 with THC; 073230 without THC .......................208 VAC, 3PH, 60 Hz, 104 amps
073231 with THC; 073232 without THC .......................240 VAC, 3PH, 60 Hz, 90 amps
073235 with THC; 073236 without THC .......................400 VAC, CE, 3PH, 50 Hz, 56 amps
073262 with THC; 073263 without THC .......................440 VAC, 3PH, 50-60 Hz, 49 amps
073233 with THC; 073234 without THC .......................480 VAC, 3PH, 60 Hz, 45 amps
073237 with THC; 073238 without THC .......................600 VAC, 3PH, 60 Hz, 36 amps
Dimensions and Weight:
Width.............................................................................28-1/4" (710 mm)
Height ...........................................................................35-1/2" (900 mm); 40-3/4" (1035 mm) on CE units
Depth ............................................................................41-1/4" (1045 mm)
Weight...........................................................................780 lbs (351 kg); 800 lbs (363 kg) on CE units
Cooling..........................................................................Forced Air (Class F)
Coolant Tank Capacity..................................................2.9 gallons (11 liters)
Maximum cutting thickness...........................................2" (50 mm)
Maximum current at 100% duty cycle...........................200 amps
Plasma and Shield Gas Flow........................................Refer to the Cut Charts in the Operation section for specific gas
requirements.
Water coolant flow rate .................................................0.8 gpm (3.0 l/min)
Weight...........................................................................3 lbs (1.36 kg)
Figure 2-1 LHF Machine Torch (standard torch shown. See Section 6 for figure of stainless steel torch)
6"
(152 mm)
15.4"
(391 mm)
23.25"
(590 mm)
2"
(51 mm)
4.3"
(109 mm)
2" (50 mm) or
1.75" (44 mm)
See Sect. 6
HySpeed LHF Machine Torch

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm HySpeed HT2000LHF and is the answer not in the manual?

Hypertherm HySpeed HT2000LHF Specifications

General IconGeneral
BrandHypertherm
ModelHySpeed HT2000LHF
CategoryWelding System
LanguageEnglish

Related product manuals