Gas Console Connections
See page 3-9 for gas console connection to power supply.
Argon-Hydrogen Cable – Power Supply to Argon-Hydrogen Manifold
See the appendix section for Argon-Hydrogen installation and operation.
INSTALLATION
3-14 HySpeed HT2000LHF Instruction Manual
6
11X1
Hold Cable – Power Supply 1 to Power Supply 2
Color TB3 Signal
Black 13 Hold Signal
Red 14 Hold Common
Shield 15 Hold Shield
Part No. Length
023340 15 ft (4.6 m)
023341 25 ft (7.6 m)
023342 50 ft (15 m)
023343 100 ft (30.5)
023344 150 ft (46 m)
12
13
Initial Height Sensing Cable – Power Supply to Initial Height Sensing Console
See the appendix section for Initial Height Sensing connections.
14
Shield Gas Hose – Gas Console to Power Supply
Note: Turn counterclockwise to tighten
15
15
12
Part No. Length
024348 5 ft (1.5 m)
024313 10 ft (3 m)
024302 15 ft (4.6 m)
024349 20 ft (6.1 m)
024303 25 ft (7.6 m)
024350 30 ft (9.1 m)
024351 35 ft (10.7 m)
024352 40 ft (12.2 m)
024353 45 ft (13.7 m)
024304 50 ft (15 m)
024305 75 ft (23 m)
024306 100 ft (30.5 m)
024312 150 ft (46 m)
Timer/Counter Cable – Power Supply to Timer/Counter
11
11
Part No. Length
023687 10 ft (3 m)
023692 25 ft (7.6 m)
023758 38 ft (11.6 m)
023693 50 ft (15 m)
123046 60 ft (18.3 m)
023694 75 ft (23 m)
123079 85 ft (25.9 m)
023695 100 ft (30.5)
023993 115 ft (35.1 m)
123189 120 ft (36.6 m)
023696 150 ft (46 m)
023954 200 ft (62 m)
11x1 TB3 Color Signal
1 2 White Starts and Arc time (CON1 Closed)
2 1 Black Starts and Arc time (CON1 Closed)
3 3 Drain Drain
15 5 Red Error Counter (Ramp Down Error)
16 4 Black Error Counter (Ramp Down Error)
12 6 Drain Drain