INSTALLATION
HySpeed HT2000LHF Instruction Manual 3-7
6
Power Cable from LHF Power Supply to Power Source.
1. Be certain that the line disconnect switch is in the OFF position and remains in the OFF position for the
remainder of the installation of the LHF system.
2. Connect the power cord leads to the line disconnect switch following local and applicable electrical codes.
Torch Lifter Requirements
The LHF system requires a high-quality, motorized torch lifter with sufficient travel to cover all cutting thickness
requirements. The lifter must provide 10 inches (254 mm) of vertical travel. The unit should have a constant
speed of at least 20 ipm (508 mm/min) with positive braking. A unit which drifts through the stop point is not
acceptable.
Optional Equipment
Water Muffler
Refer to Water Muffler instruction manual 802050. A power cable for the Water Muffler pump must be provided by
the customer. The pumps provided by Hypertherm take a three-phase input. Part numbers and corresponding
voltages are listed in the Water Muffler manual. Input current information is provided on the motor data plate.
Present pump systems all draw less than 20 amps and cable sizes should be selected accordingly.
The water muffler cannot be used with the stainless steel torch.
System Units Placement
Position all required units prior to making electrical, gas and interface connections.
Ground all external modules in the LHF system to earth.
To prevent leaks in the system, tighten all gas and water connections to the following specifications:
Use 2 wrenches when tightening to prevent damage to the mating component.
Use the diagram on the following 2 pages to make system interconnections. Follow the number guide on the
diagram to find out specific information on each cable, hose or connection. The numbered items are detailed on the
pages following the interconnection diagram.
Gas or water
Torque Specification
hose size lbf-in lbf-ft kgf-cm
up to 3/8" 75-85 6.25-7 86-98
1/2" 360-480 30-40 415-550

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm HySpeed HT2000LHF and is the answer not in the manual?

Hypertherm HySpeed HT2000LHF Specifications

General IconGeneral
BrandHypertherm
ModelHySpeed HT2000LHF
CategoryWelding System
LanguageEnglish

Related product manuals