EasyManuals Logo
Home>Hypertherm>Welding System>HySpeed HT2000LHF

Hypertherm HySpeed HT2000LHF User Manual

Hypertherm HySpeed HT2000LHF
202 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #62 background imageLoading...
Page #62 background image
OPERATION
HySpeed HT2000LHF Instruction Manual 4-9
6
Adjust Cut Flow Gases and Prepare for Cutting
13. Set S2 on the gas console to Test Cut Flow.
14. Look at the oxygen (FM2) and/or nitrogen / air (FM1) flowmeters on the gas console and set the Cut Flow
plasma gas flow rate % by referring to the Cut Charts and adjusting the Plasma Cut Flow metering valve
(MV1).
Note: If you have changed consumable parts or if the power supply has been off for more than 1 hour, purge gas
lines by leaving the system in Test Cut Flow for one minute.
15. Set S2 to Run after the test preflow and test operate flow rates have been set.
The system is now ready for operation.
Common Cutting Faults
Torch pilot arc will initiate, but will not transfer. Causes can be:
1. Work cable connection on the cutting table is not making good contact.
2. Malfunction in the system. See Section 5.
The workpiece is not totally penetrated, and there is excessive sparking on top of the workpiece. Causes can be:
1. Current is set too low (check Cut Chart information).
2. Cut speed is too high (check Cut Chart information).
3. Torch parts are worn (see Changing Consumable Parts).
4. Metal being cut is too thick.
Dross forms on the bottom of the cut. Causes can be:
1. Cutting speed is too slow or too fast (check Cut Chart information).
2. Arc current is set too low (check Cut Chart information).
3. Torch parts are worn (see Changing Consumable Parts).
Cut angle is not square. Causes can be:
1. Wrong direction of machine travel.
High quality side is on the right with respect to the forward motion of the torch.
2. Torch-to-work distance is not correct (check Cut Chart information).
3. Cutting speed is not correct (check Cut Chart information).
4. Arc current is not correct (check Cut Chart information).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm HySpeed HT2000LHF and is the answer not in the manual?

Hypertherm HySpeed HT2000LHF Specifications

General IconGeneral
BrandHypertherm
ModelHySpeed HT2000LHF
CategoryWelding System
LanguageEnglish

Related product manuals