1X10
INSTALLATION
HySpeed HT2000LHF Instruction Manual 3-13
6
Programmable Remote Voltage and Current Cable – Power Supply to Programmable Remote
Note: If you are using the digital remote to set voltage and current, skip this reference.
8
8
1X5
5X2
1X7
15X1
Current Control Cable – Power Supply to Remote Current Control
Note: If you are using the digital remote, programmable remote or machine computer to set current, skip
this reference.
9
9
Water Muffler Pump Cable – Power Supply to Water Muffler Pump
See water muffler instruction manual 802050 to connect cable to pump motor, and to make remaining water
muffler connections. The water muffler cannot be used with the stainless steel torch.
10
10
1x5 5x2 Color Signal
10 10 Black/Green Voltage 20
11 11 Black/Orange Voltage 40
12 12 Black/Red Voltage 80
13 13 White/Green Voltage 100
14 14 White/Red Voltage 200
15 15 Black/White Spare
16 16 Shld Shield
1x5 5x2 Color Signal
1 1 Black Current 20
2 2 Blue Current 40
3 3 Green Current 80
4 4 White Current 100
5 5 Orange Current 200
7 7 White/Black Common
8 8 White/Blue Voltage 5
9 9 Black/Blue Voltage 10
Part No. Length
023834 15 ft (4.6 m)
023835 25 ft (7.6 m)
023836 50 ft (15.3 m)
023837 75 ft (22.9 m)
023838 100 ft (30.5 m)
Part No. Length
023898 125 ft (38.1 m)
023839 150 ft (45.8 m)
023840 200 ft (61 m)
023899 250 ft (76.3 m)
023900 275 ft (83.9 m)
023901 300 ft (91.5 m)
Part No. Length
123150 10 ft (3 m)
023871 25 ft (7.6 m)
023872 38 ft (11.6 m)
023873 50 ft (15 m)
023874 75 ft (23 m)
023875 100 ft (30.5 m)
123068 110 ft (33.6 m)
123277 120 ft (36.6 m)
123088 125 ft (38.1 m)
023876 150 ft (46 m)
123032 170 ft (51.9 m)
023877 200 ft (61 m)
Part No. Length
023866 50 ft (15 m)
023867 75 ft (23 m)
023868 100 ft (30.5)
1X7 15X1 Color Current Signal (I)
2 8 Black I-10
3 7 White I-20
4 10 Black I-40
5 9 Green I-80
6 15 Black I-100
7 16 Red I-200
11 3 I-Com
From 1X10 Color To WM Pump Contactor
2 Black Coil
4 White AC Neut.
3 Green Ground