1X1
INSTALLATION
3-12 HySpeed HT2000LHF Instruction Manual
6
Note: If you are using a machine computer interface to set voltage and current and do not want the programmable
voltage current readout, skip references 7-9.
Remote Voltage and Current Cable – Power Supply to Digital Remote or Programmable Remote
1x4 5x1 Color Signal
4 1 Green SID Data
8 2 Black SID Common
13 Grn/Blk Shield
9 3 Red SOD Data
15 6 Black SOD Common
14 Red/Blk Shield
35 7 White AC Power
36 8 Black AC Power
31 Wht/Blk Shield
5 Key
22 Key
6
6
Notes: • If using this Remote I/O Cable, remove jumpers from power supply
TB5 terminals 1&2 and 4&5 and terminate Remote I/O Cable wires for
PB2A and PB2B to a normally closed switch.
• Terminate wires for PB1A and PB1B to a normally open switch.
• Input requirements for interlocks: DC current between 15 and 20 mA; DC
voltage between 12 and 15 V.
• Refer also to pages 3 and 6 of the wiring diagrams in Section 7.
Remove jumper Remove jumper
7
7
1X4 5X1
Part No. Length
123294 6 ft (1.8 m)
123295 15 ft (4.6 m)
123296 25 ft (7.6 m)
123297 35 ft (10.7 m)
123298 50 ft (15.3 m)
123299 60 ft (18.3 m)
123300 75 ft (23 m)
Part No. Length
123301 85 ft (25.9 m)
123302 100 ft (30.5)
123303 115 ft (35.1 m)
123304 120 ft (36.6 m)
123305 125 ft (38.1 m)
123306 150 ft (46 m)
123307 200 ft (62 m)
Remote I/O Cable – Power Supply to Remote Interface
1x1 Color Signal
19 White FS1 Interlock
20 Red FS1 Interlock
13 Shield Ground
23 Blue LT1 120 VAC
24 Black LT1 120 VAC
25 Shield Ground
26 Red PB2A 24 VAC
27 Green PB2A 24 VAC
28 Shield Ground
29 White PB2B 120 VAC
30 Black PB2B 120 VAC
34 Shield Ground
32 Brown PB1A 24 VAC
33 Black PB1A 24 VAC
37 Shield Ground
35 Red PB1B 120 VAC
36 Brown PB1B 120 VAC
31 Shield Ground
1x1 Color Signal
2 Yellow PB1 LT1 24VAC
3 Black PB1 LT1 24VAC
7 Shield Ground
5 Orange TS1 Interlock
6 Black TS1 Interlock
1 Shield Ground
8 Red LS1 Interlock
9 Black LS1 Interlock
4 Shield Ground
11 Green PS3 Interlock
12 Black PS3 Interlock
18 Shield Ground
14 Red PS1,PS2 Interlock
15 Blue PS1,PS2 Interlock
21 Shield Ground
16 Red TS2 Interlock
17 Yellow TS2 Interlock
10 Shield Ground
Part No. Length
023990 7 ft (2.1 m)
023911 15 ft (4.6 m)
023878 25 ft (7.6 m)
023879 50 ft (15.3 m)
123040 60 ft (18.3 m)
023880 75 ft (22.9 m)
123073 85 ft (25.9 m)
023881 100 ft (30.5 m)
Part No. Length
123188 120 ft (36.6 m)
023882 125 ft (38.1 m)
023883 150 ft (45.8 m)
023884 200 ft (61 m)
023885 250 ft (76.3 m)
023886 275 ft (83.9 m)
023887 300 ft (91.5 m)
WARNING
• Be certain to properly terminate 120 VAC wire connections!
• Provide proper strain relief for remote I/O cable at customer interface.