Powermax105 Operator Manual 8-7
Fault
code
Description Power
LED
Fault
LED
Fault
icon
Solutions
0-30 Torch consumables stuck
This indicates either a
“torch stuck open” or
a “torch stuck closed”
situation.
On On • If the consumables became loose or were
removed while the power supply is ON, turn
OFF the power supply, correct the problem and
then turn ON the power supply to clear this
fault.
• Change consumables.
• If the consumables appear to be installed
correctly, the torch may be damaged. Contact
your Hypertherm distributor or authorized repair
facility.
0-32 End of consumable life On On
• Replace the electrode and nozzle.
• Check the remaining consumables for wear and
replace as needed.
0-40 Over/under temperature On On
• Leave the power supply on to allow the fan to
cool the power supply.
• If the internal temperature of the power supply
approaches -30°C (-22°F), movethe power
supply to a warmer location.