Figure 2. Locations of DIMM 0, DIMM 1, DIMM 2 and DIMM 3 on 2892 Integrated xSeries Server (IXS)
card.
In both figures, the second DIMM from the top of the IXS card (DIMM 1) is the failing item. To determine
the part number, go to symbolic FRU “MEMORY” on page 401.
This ends the procedure.
DIMM 2
For use by authorized service providers.
Use this page to view the locations of DIMM 0, DIMM 1, DIMM 2 and DIMM 3 on the 2890 and 2892
Integrated xSeries Server (IXS) card.
Figure 1. Locations of DIMM 0, DIMM 1, DIMM 2 and DIMM 3 on 2890 Integrated xSeries Server (IXS)
card.
Figure 2. Locations of DIMM 0, DIMM 1, DIMM 2 and DIMM 3 on 2892 Integrated xSeries Server (IXS)
card.
328 iSeries: iSeries Server 270, 800, 810, 820, 825, 830, 840, 870, 890, SB2, and SB3 Hardware Problem Analysis and
Isolation