This ends the procedure.
ANYBRDG
For use by authorized service providers.
Any cable, card, or card enclosure connected to the Multi-adapter bridge may be causing the problem.
The card that reported the problem may not be causing the problem. Multi-adapter bridge domains are
labeled PCI Bridge Set inside the tower. Find the location of the card reporting the problem and its
corresponding PCI Bridge Set. Any cable, card, or card enclosure connected to this PCI Bridge Set may
be causing the problem.
ANYBUS
For use by authorized service providers.
Any cable, card, or card enclosure may be causing an IOP-detected bus error. The IOP that is reporting
the problem may not be causing the problem.
ANYFC
For use by authorized service providers.
Any IOA, hub, gateway, or device attached to the same Fiber Channel interface may be failing.
ANYMEM
For use by authorized service providers.
Follow the instructions for the model on which you are working:
v Model 270 (See page 279)
v Models 800 and 810 (See page 279)
v Model 820 (See page 280)
v Model 825 (See page 280)
v Models 830 and SB2 (See page 281)
278 iSeries: iSeries Server 270, 800, 810, 820, 825, 830, 840, 870, 890, SB2, and SB3 Hardware Problem Analysis and
Isolation