Manufacturer Model Range (ohm)
Accuracy at 1.0 ohm
or less Fail criteria (ohm)
Fluke 10 400 +/-0.20 +0.50
Fluke 11 400 +/-0.20 +0.50
Fluke 110 600 +/-0.20 +0.50
Fluke 111 600 +/-0.20 +0.50
Fluke 112 600 +/-0.20 +0.50
Fluke 12 400 +/-0.20 +0.50
Fluke 12B 400 +/-0.20 +0.50
Fluke 16 400 +/-0.20 +0.50
Fluke 175 600 +/-0.20 +0.50
Fluke 177 600 +/-0.20 +0.50
Fluke 179 600 +/-0.20 +0.50
Fluke 18 400 +/-0.20 +0.50
Fluke 21-2 320 +/-0.20 +0.50
Fluke 21-3 320 +/-0.20 +0.50
Fluke 23-2 320 +/-0.20 +0.50
Fluke 26-3 400 +/-0.20 +0.50
Fluke 29-2 400 +/-0.20 +0.50
Fluke 70-2 320 +/-0.20 +0.50
Fluke 70-3 320 +/-0.20 +0.50
Fluke 73 320 +/-0.20 +0.50
Fluke 73-2 320 +/-0.20 +0.50
Fluke 73-3 320 +/-0.20 +0.50
Fluke 75 320 +/-0.20 +0.50
Fluke 75-2 320 +/-0.20 +0.50
Fluke 75-3 320 +/-0.20 +0.50
Fluke 76 400 +/-0.20 +0.50
Fluke 77 320 +/-0.20 +0.50
Fluke 77-2 320 +/-0.20 +0.50
Fluke 79-2 400 +/-0.20 +0.50
Fluke 79-3 400 +/-0.20 +0.50
Fluke 83 (with CAT III front
panel marking)
400 +/-0.20 +0.50
Fluke 83-3 400 +/-0.20 +0.50
Fluke 85 (with CAT III front
panel marking)
400 +/-0.20 +0.50
Fluke 85-3 400 +/-0.20 +0.50
Fluke 87 (with CAT III front
panel marking)
400 +/-0.20 +0.50
Fluke 87-3 200 +/-0.20 +0.50
Testing MCM and L3 modules for a short circuit: For use by authorized service providers.