Ethernet switches Code 8
Severity of the error
The element x indicates the severity of the error. The value x can be:
v A for Action: GUI error messages. The user must perform a specific action.
v C for Critical: A critical error occurred which must be corrected by the user or
system administrator.
v D for Debug: Used only for debug purposes.
v I for Informational: No operation action required.
v W for Warning: An error occurred that should be investigated and fixed.
Error code examples
These two error code examples illustrate how to interpret the alphanumeric
elements based on the information provided above.
Example 1
Source: Network problems between the third file module and the management
node.
Error code and message:
210000x The Ethernet port0 has failed and is unresponsive.
210001x A network failure was detected between Ethernet port 0 (mgmt0sl0) and
the management node. Link down.
210002x A network degradation was detected between Ethernet port 0
(mgmt0sl0) and the management node. There are high packet losses occurring.
210003x A network degradation was detected between Ethernet port 0
(mgmt0sl0) and the management node. High collisions detected.
The following table shows the break down of the error code's alphanumeric
elements:
Table 31. Error code break down
ACDXXXx
210nnnx
2 File Module
1 Built in Ethernet port 0
0 Originated with Denali checking
nnn Unique error code
x Severity of the error
Example 2
Source: A disk drive problem in the fourth storage pod, second expansion drawer.
Error code and message:
Chapter 4. File module 79

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Storwize V7000 2076-224 and is the answer not in the manual?

IBM Storwize V7000 2076-224 Specifications

General IconGeneral
BrandIBM
ModelStorwize V7000 2076-224
CategoryStorage
LanguageEnglish

Related product manuals