7. See Figure 10 on page 63 for an example of status when there is no mirror.
If mirroring is not enabled, the output under Mirror Information displays a
message that says: The mirror is not created/configured.
If the mirror is not created, refer to “Troubleshooting the System x3650” in the
IBM Storwize V7000 Unified Information Center for information on launching the
LSI configuration tool.
Target on ID #5
Device is a Hard disk
Enclosure # : 1
Slot # : 1
Connector ID : 1
Target ID : 5
State : Out of Sync (OSY) <---
Size (in MB)/(in sectors) : 286102/585937500
Manufacturer : IBM-ESXS
Model Number : XXXXXXXXXXXX
Firmware Revision : XXXX
Serial No : XXXXXXXXXXXXXXXXXXXX
Drive Type : SAS
Protocol : SAS
Error Information
SMART Error Count : none
SMART ASC : none
SMART ASCQ : none
Figure 9. Example that shows that a drive is not synchronized
62 Storwize V7000 Unified: Problem Determination Guide Version