67
5
DV MODE OPERATION
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
N EMR communication
The EMR (Enhanced Monitor Receive) communication
mode is available for digital mode operation. In the EMR
communication mode, no call sign setting is necessary.
When an EMR communication mode signal is received, the
audio (voice) will be heard at the specified level even if the
volume setting level is set to minimum level, or digital call
sign/digital code squelch is in use.
q Enter “EMR” in DV SET mode.
MENU DV SET EMR
(Push [MENU ]), (rotate [DIAL], then push [ ](MONI).)
• EMR screen is displayed.
w Rotate [DIAL] to turn the EMR communication mode ON
or OFF.
OFF : EMR communication is set OFF. (default)
ON : EMR communication is set ON.
When "ON" is selected, “EMR” appears instead of memory
channel indication.
e Push [ ](MONI).
• Returns to DV SET mode.
r Push [MENU ] to return to frequency indication.
“EMR” appears
t Push [PTT] to transmit.
y Release [PTT] to return to receive.
NOTE: The EMR communication function is turned OFF
automatically when turning transceiver’s power OFF.