SYSTEM OIL FILL
OIL FILLING POINTS
The unit is supplied without oil and must be filled with the correct quantity and specification before
starting the pump.
ADDING OIL
Before operating the CAFS system, oil must be added to the pump gearbox and
the separator tank.
GEARBOX
The oil filling point for the Gearbox housing is located as shown.
GEARBOX OIL FILLING AND CHECKING
Fill the gearbox until the oil flows from the oil fill point. This is the only accurate method of checking
that the correct amount of oil has been added to the gearbox, as it allows for different sizes of gear
ratios.
Fill the pump gearbox to the proper level (see 029-0020-63-0 Muscle Pump manual for
details). Oil must be SAE EP90, 80W90 or Synthetic 75W-140 gear oil (with an API service
rating of GL5).
Figure 30: Gearbox Oil Level Check Location (DSD Version Shown)
Gearbox Housing - Oil
Level